Name: | Description: | Used in/Using parameters: | Default expression (mm): |
HHeader | - |
Used In: HGirder (Girder) PHx, PHy, FH (Header) |
60 |
L |
Defines the real length of the box, depending on the dimension type
( DT ). However, the actual length of the base in the drawing is calculated
by taking into account not only L, but also DT and FD,and is measured through the
Lss and Lss1 parameters.
L is only used in the expressions of the actual score-to-score length parameters Lss and Lss1. This means that changing the expression of L will change the length (Lss and Lss1) of the current resizable design, too. |
Used In: TL, TO (Lock Hole) Using: ShLss (Shelf) PWGirder (Girder) LHW1 (Lock Hole) |
ShLss+2*O90y(d(Shelf), fd(Shelf))+2*(PWGirder+2*O90y(d(Girder), fd(Girder)))+2*LHW1 |
PHx | Header: - |
Using: HHeader (Header) |
HHeader-PHCorrX(d(), fd()) |
Shelf: - |
Using: HTray (Shelf) |
HTray-PHCorrX(d(), fd()) | |
PHy | Header: - |
Using: HHeader (Header) |
HHeader-PHCorrY(d(), fd()) |
Shelf: - |
Using: HTray (Shelf) |
HTray-PHCorrY(d(), fd())-O90x(d(Shelf), fd(Shelf)) | |
DC | Defines the Header distance. |
Used In: DxDCT, DxDCT1 (Header) |
DC1x(d(Header), fd(Header)) |
DxDCT | Header: Defines the horizontal size of the Header taper. |
Using: DC (Header) |
DC |
Shelf: Defines the horizontal size of the Shelf taper. |
Using: DCShelf (Shelf) |
DCShelf | |
DxDCT1 | Header: - |
Used In: LHO1 (Lock Hole) Using: DC (Header) |
DC |
Shelf: - |
Used In: LHO1 (Lock Hole) Using: DCShelf (Shelf) |
DCShelf | |
UL |
Defines whether to use layers (relative
to the number and the type of the flaps). If you imagine, that in the
current design, each two opposite side flaps form a layer, then the other
two opposite ones form another layer that overlaps the first one. Therefore,
if the number of the layers is n,
you have to apply 'n-1' corrections
to the sides adjoining the respective flaps (layers). Of course, the
Layers Parameters take into account all these corrections.
UL is a selection type parameter - it uses Boolean selection type , predefined in the Corrugated parameter template. The 2 predefined entries are as follows:
To change the expression of UL, click in the Expression column field of UL in the Parameters tabular pane tab and select the desired option from the list. |
Used In: LHO1 (Lock Hole) FH (Header) |
Yes |
LSC | Defines the layer step crease. |
Used In: LHO1 (Lock Hole) FH (Header) |
LSCf(d()) |
FH | Header: Defines the flap height. |
Using: HHeader, UL, LSC (Header) |
HHeader+UL*LSC |
Shelf: Defines the flap height. |
Using: HLShelf, ShWss, HTray (Shelf) UL, LSC (Header) |
HTray+UL*LSC | |
DXT | - | - | DxT(d()) |
DxT1 | - |
Used In: DyT1 (Header) |
d() |
DyT1 | - |
Using: DxT1 (Header) |
DxT1 |