Name: Description: Used in/Using parameters: Default expression (mm):
H Defines the realheight of the box, depending on the dimension type ( DT ). However, just like the L and W, the actual height of the base in the drawing is calculated by taking into account not only H, but also DT and FD, and is measured through the Hssparameter. Used In:
HssX
(Tray)
H1
(Inside Panel)
HssY
(Tray)
Using:
b
(Main)
2*b
LHW1 - Used In:
Wss
(Tray)
HWDC2y(d(Tray), fd(Tray))
Wss Defines the real score-to-score width taking into account the corrections due to the two folds and the width layers correction. Used In:
L1
(Header)
Using:
W1Shelf
(Shelf)
LHW1
(Tray)
W1Shelf+2*LHW1
HssX - Used In:
PH1
(Body)
PHx
(Tray)
IPH1, TPH
(Header)
Using:
DT
(Main)
H
(Tray)
H+C90x(d(Tray), fd(Tray), DT)+HCODCx(d(Tray), fd(Tray), DT)
UL Defines whether to use layers (relative to the number and the type of the flaps). If you imagine, that in the current design, each two opposite side flaps form a layer, then the other two opposite ones form another layer that overlaps the first one. Therefore, if the number of the layers is n, you have to apply 'n-1' corrections to the sides adjoining the respective flaps (layers). Of course, the Layers Parameters take into account all these corrections.

UL is a selection type parameter - it uses Boolean selection type , predefined in the Corrugated parameter template. The 2 predefined entries are as follows:

  • Yes - use this type when you wish to use layers, ie. whwn there are overlapping layers (flaps, tucks and etc.)the system to take it into account when calculating the design ( in this case L=Lss ).

  • No - use it when you do not have to use layers or the corrections may be neglected.

To change the expression of UL, click in the Expression column field of UL in the Parameters tabular pane tab and select the desired option from the list.

Used In:
FH
(Shelf)
FH1
(Flaps)
Yes
Lss Defines the real score-to-score length (real length of the box taking into account all corrections applied). Using:
NyCells, CellH
(Main)
HSW
(Tray Hole Segments)
LHW
(Lock Hole)
NyCells*CellH+(NyCells-1)*HSW+2*LHW
HssY - Used In:
PHy
(Tray)
FH
(Shelf)
FH1
(Flaps)
Using:
DT
(Main)
H
(Tray)
H+C90y(d(), fd(), DT)+HCODCy(d(), fd(), DT)
PHx - Using:
HssX
(Tray)
HssX-PHCorrX(d(), fd())
PHy - Using:
HssY
(Tray)
HssY-PHCorrY(d(), fd())